Welcome to Shanghai! Our main products: magnetic shutter level gauge, ultrasonic and magnetic level gauge

High voltage maglev floater

The UHC series high-voltage inspcetion liquid level gauge is suitable for high pressure liquid conta…

Description:

The UHC series high-voltage inspcetion liquid level gauge is suitable for high pressure liquid container turning, the position of the measurement and control.Clearly indicates that the height of liquid level, direct display striking, indicator and completely isolated storage tank, the use of safe, reasonable design, simple structure, convenient installation and reliable, stable performance, long service life, low maintenance cost, easy installation and maintenance, etc.
Users can according to the requirements of the project, cooperate with remote transmitter use, can be realized on the digital display, as well as the standard of 4 ~ 20 ma output far eastone electrical signals, to match the recording instrument, or the needs of the industrial process control.Can also be used with magnetic control switch or close to switch, etc, the liquid level monitoring alarm and control into the liquid equipment.

High pressure inspcetion flap liquidometer technology parameters
Measuring range: 200...~ 15000 ㎜ (more than 6000 mm or transportation conditions are not allowed to exceed the length of the liquid level meter can be procurement section)
Display precision: plus or minus 10 mm;
Pressure of work: 6.3, 10.0, 16.0, 10.0 MPa;
Medium temperature: - 20 ℃ ~ 450 ℃;
Medium density: p. 0.5 g/cm3;
Medium density difference: p. 0.15 g/cm3 (measuring the position)
Medium viscosity: 0.4 Pa s. or less;
Process connections: 3/4 "/ 25 PN1.0 (executive standard HG20592 ~ 20635-97), if you need other standard can be made according to customer's requirement.
Liquid material: 316 ss, 316 l, and so on
(according to the chemical properties and the use of medium temperature pressure selection).
Float material: 316 ss, 316 l, titanium, etc.

High pressure inspcetion flap liquidometer order options table

Level gauge

type

In situ shows that the output4-20mA And the lower limit alarm (switch forms: normally open or normally closed, keep type, explosion-proof type)

The output4-20mAAnd upper and lower limit alarm HARTagreement RS485The bus

Working temperature

- 20 ~ 450 ℃ ℃ (According to the customer request)

Measuring range

L= ㎜ (according to customer requirements:200....~15000㎜)

Measuring the dielectric

(According to the customer request)

Medium density

g/cm3(according to the customer to provide:≥.0.5g/cm3)

Design pressure

≤6.3Mpa ≤10.0Mpa ≤25Mpa otherMpa

The actual pressure

≤6.3Mpa ≤10.0Mpa ≤25Mpa otherMpa

Process connection

DN20 PN1.0 DN25 PN1.0 other:DNPN(According to the customer request)

Other requirements

explosion-proof(flameproof) other