Isolate the security gate

Will come from the safety of single/double channel voltage signal, through the security gate to isol…

Description:

Isolated safety barrier properties:
Will come from the safety of single/double channel voltage signal, through the security gate to isolate single/double output current or voltage signals to the danger zone, can control of danger such as actuator (electric/gas converter), and other instruments.It is intelligent safety barrier product, with functions of on-line fault self-diagnosis, users can also be through a dedicated handheld programmer for our products in Chinese input signal type and output range of Settings.

Explosion-proof marks:
[Exia]ⅡC
Transmission accuracy:
±0.1%F.S
Channel number:
Single/double channel

The safety barrier of danger output signal:
4-20 ma dc current:
Signal types and range in order to determine, is available
The output load capacity:
4-20 ma: 0 ~ 500 Ω;0 to 10 ma: 0 ~ 1 k Ω
O (1) - 5 v: 500 k or higher Ω;0 to 10 v: 1 m or more Ω
(need higher load capacity when ordering, please)
The security gate safety input signals:
Dc voltage: 1 ~ 5 v
Input impedance: 500 k Ω or higher
Note: need to 0 ~ 5 v, 2 ~ 10 v, 0 ~ 10 v, etc. When ordering, please determine signal types, programming is available.

National anti-explosive electric products quality supervision and inspection center (CQST) explosion-proof certification parameters (between terminals 1 and 2), (4, 5) between terminals:
Um=250VAC/DC Uo=28.4V Io=88mA,Po=624mW,
Ⅱ C: Co = 0.055 u F, Lo = 3.2 mH,
Ⅱ B: ICo = 0.44 u F, Lo = 9.6 mH,
Ⅱ A: ICo = 1.45 u F, Lo = 25.6 mH,

Power consumption:
1.1 W (24 power supply, single channel 20 ma output)
1.8 W (24 power supply and two-way 20 ma output)

The panel light:
The normal work of the instrument, the indicator light PWRS normally on;
Input signal fault alarm, the indicator light ALM (dual channel CH1 and CH2) or normally on.
The school must:
This product USES intelligent digital design, which can ensure the accuracy of within the scope of the provisions of this manual.For calibration please matching the company to provide dedicated handheld programmer in Chinese.

Connection of the equipment and areas are:
Electricity/gas converter, electric valve positioner
0, 1, 2, A and B Ⅱ Ⅱ, Ⅱ C, T4 and T6, danger zone
The security gate selection methods:


Type no.

Said Ming


ZY-AQS

Testing end secure

Voltage signal input

Input channel





The default for single channel

D




Double input channel (width to 18 mm)

The first output

1



4-20mA

2



1-5V

3



0-10mA

4



0-5V

5



0-10V

6



0-20mA

The second output



The default without the second output

1


4-20mA

2


1-5V

3


0-10mA

4


0-5V

5


0-10V

6


0-20mA

Communication function (choose the no second output function)


Default is no communication function

T1

485 communications (single output only)

T2

232 communications (single output only)

Ming said:

Voltage input types and corresponding output range. When ordering, please indicate. If users need to programming, equipped with the company, please provide a special hand-held programmer in Chinese.Specific operation and calibration methods refer to the manual programming and calibration technology.

The security gate wiring diagram:

Single channel instrument connection width x height x deep (12.8 x 100 x 115 mm)

Dual channel double output instrument connection width x height x deep (18 x 100 x 115 mm)


Operating side safety barrier - voltage signal input single/double channel security gate