Welcome to Shanghai! Our main products: magnetic shutter level gauge, ultrasonic and magnetic level gauge
86-021-56901458
Address:No. 107 Nanshan Road, Shanghai, Jingan District
Tel:86-021-56901458
Fax:86-021-33250243
Email:13817864195@139.com

The diaphragm pressure gauge

YMF diaphragm pressure gauge to enlarge the using range of all kinds of universal pressure gauge, ca…

Description:

A, use:

YMF diaphragm pressure gauge to enlarge the using range of all kinds of universal pressure gauge, can be suitable for measuring the corrosive, high temperature, high viscosity, easy to crystallization, easy to solidification and have solid suspended matter medium pressure, and for some measurement medium can not directly into the universal instrument and easy to clean to prevent the pressure testing of the occasions where the precipitation, must adopt the diaphragm isolator with universal pressure gauge table to form a system of diaphragm.
Diaphgram gauge is mainly used in petroleum, chemical, pharmaceutical, food, textile and other industrial department the pressure test in the process of production.
Second, the diaphragm pressure gauge system structure diagram:
The diaphragm pressure gauge structure form

Three, diaphragm pressure gauge structure principle:

Diaphragm pressure gauge by all sorts of general and different structure diaphragm type pressure gauge isolator to form a closed system, the sealing liquid filling.

When the measured medium pressure acting on the diaphragm, diaphragm deformation, compression sealing fluid in a closed system.Due to the inherent nature of sealing fluid,

Make the elastic element of pressure gauge produces corresponding elastic deformation, displacement, by indicating device shows pressure value.When the diaphragm of the enough stiffness,

The pressure meter indicates nearby in the pressure value of the measured medium.
Four main technical indicators, diaphragm pressure gauge:

Temperature characteristic of diaphragm table
Because the diaphragm table filled the sealing liquid system as the pressure transmission medium, and the quantity of the diaphragm table temperature sealing liquid expansion coefficient,

Compression of the diaphragm stiffness and parts related to the temperature.For the influence of low range pressure meter is especially striking.General compression zone temperature error is not more than 1.0% / ℃, so the temperature of the diaphragm table is generally by the universal pressure gauge temperature affects measure and diaphragm separator compression zone temperature influence both combined.
Diaphragm table level difference
Especially for diaphragm table with soft connecting pipe, because the diaphragm compression zone and universal pressure gauge installation position is not in the same horizontal plane,

Delta P will produce the effect of liquid level difference.More attention should be paid to in precise measurement.
Diaphragm table of corrosion resistance
Diaphragm table of corrosion resistance can be suitable for the selection and measurement of media contact part of the diaphragm, the flange and the sealing gasket materials to ensure that.
Diaphragm material: 0 cr17ni12mo2 (316);Monel alloy (Cu30Ni70);Hartz alloy (H276C);Tantalum (Ta) and fluorine plastic (F4).
The flange material: stainless steel 0 cr17ni12mo2 (316);Stainless steel lined with fluoroplastic (316 + F4).
Nitrile rubber sealing gasket material:;Fluorine rubber;Silicone rubber and fluorine plastic.
The choice of diaphragm liquid
Reliability and safety guarantee diaphragm table is used, should choose appropriate sealing fluid according to different purposes.

Five, the diaphragm pressure gauge selection table
Diaphragm pressure gauge selection table

Six, diaphragm device flange size:

1. Open the convex flange

Code name

The upper limit range P (MPa)

Recommend the flange standard code

Tu face flange dimensions (Mm)

Size chart

D

K

f

f

L

C

B

MF1

4

JIS-10/20K 50A

155

120

100

3

19

18

50

FIG. 1

4

50-1.0/4.0HGJ46

160

125

100

3

19

18

50

4

ANSI-2B 150LB

152

121

92.1

3

19

18

2. ""

4

ANSI-2B 300/100LB

165

127

92.1

3

19

18

2. ""

6 ~ 10

25-10.0 HGJ47

125

89

50.8

7

20

20

25

Figure 2

6 ~ 10

25-10.0 HGJ47

165

127

92.1

3.5

20

26

50

16 and 25

20~25.0 HGJ53

130

89

43

7

22

20

25

MF

4

25-4.0 DIN

115

85

65

3

M12

26

25

FIG. 3


* all can according to the user or the specified flange standard size manufacturing
Diaphragm pressure gauge installation form
2. The i-section convex flange [code] MG range limit: 4 mpa or less

Recommend the flange standard code size 25 k a25125907019js1 DNd1Kd2LJS1-10/25-10/20 k, 20 k 15 a1595705215ansi a20100755815js1-10/20-1 b - 151 - b1 "b1 10879.450.819.1 ANSI - 1 b - 300/6001" HGJ4720105755614 12488.950.819.120-1.0/4.0

I-section installation

The diaphragm body installation

3. The nipple type (ML) the upper limit range: 60 mpa or less

4. Screw type diaphragm isolator/code MZ
Measuring range: 1 ~ 25 mpa
The diaphragm and diaphragm material: 0 cr17ni12mo2 (316).

5. Clamp the diaphragm separator [code MC]
6. Nut type diaphragm isolator code [MN]
7. The rectangular flange diaphragm separator [code MH]
Note: 5 and 7 are seen health type diaphragm pressure gauge page.
The attachment, about the isolation diaphragm part corrosion resistant material choice

Corrosive medium

Corrosion resistant materials

Tin bronze (QSn6.5-0.4)

SUS316

Pure tantalum (Ta)

Monel (Ni70Cu30)

Hartz (HC)

Ptfe (F4)

Sulfate (- H2SO4)

V

delta

a.

V

V

V

Nitric acid (HNO3)

V

a.

V

V

Hydrochloric acid (HCI)

delta

a.

V

V

Phosphoric acid (H3PO4)

V

V

a.

V

V

V

Acetic acid (CH3COOH)

V

V

a.

V

a.

V

Caustic soda (NaOH)

delta

a.

delta

a.

a.

V

Soda ash (Na2CO3)

a.

a.

a.

a.

V

V

Sodium bicarbonate (NaHCO3)

V

a.

a.

a.

a.

V

Chlorine (CI)

Dry: V
Wet: ╳

Dry: V
Wet: ╳

a.

Dry: V
Wet: ╳

V

V

Bromide (Br2)

Dry: delta
Wet: ╳

Dry: ╳
Wet: delta

a.

Dry: a.
Wet: ╳

a.

V

Ammonia (NH3)

V

a.

V

Water (30% NaCI)

V

V

a.

a.

a.

V

Symbol explanation: "- the best;Delta - conditional use;V - you can use;╳ - may not be used.


Find out more about the products, technologies and solutions you need. Please leave us a message

Browse:
Return To The Top