Pervious to light glass level gauge
Product overview
UB series, ordinary, high temperature, high pressure and low temperature frost, bore diameter glass level gauge can be directly used to indicate all kinds of industrial containers within the medium level.Used in working temperature below 260 ℃ after heat treatment of borosilicate glass, above 260 ℃ are heat treated after special processing of aluminum silicate glass, can withstand the temperature 420 ℃ medium.On the liquid surface covering a layer of mica.
UBD type bore diameter glass level gauge is designed for petrochemical installations in more viscous medium level measurement and the design and manufacture.Instrument measuring range, and wide caliber, fast speed, no congestion, at both ends, no blind area, it is mainly used for petrochemical installations in the non-crystalline medium level of the on-site instructions, particularly applicable to flammable, explosive and more viscous medium level measurement.
UBDD frost prevention type low temperature glass level gauge is designed for measuring the liquid level of low temperature medium instrument, through frost prevention fin can be clearly observed that the measured medium level.Instrument structure is simple, safe and reliable, durable.
The product selection
UB | Ordinary, high temperature, high pressure, low temperature frost prevention glass level gauge | Registration type | ||||||
25 | Class 150LB ANSI PN2.5Mpa | Classes. | ||||||
60 | Class 300LB ANSI PN6.4Mpa | |||||||
100 | Class 600LB ANSI PN10.0Mpa | |||||||
160 | Class 900LB ANSI PN16.0Mpa | |||||||
A | Pervious to light type, suitable for colorless transparent liquid measurement, and light is a good place | Basic types of | ||||||
B | Pervious to light with the steam heating, suitable for cold area or liquid heating | |||||||
C | Color liquid of a reflex, is suitable for the measurement, and light is a good place | |||||||
D | Reflection type with steam heating, used in cold areas or liquid heating | |||||||
E | Good type of two-color pervious to light, can be used to light and colorless transparent liquid (not recommended) | |||||||
F | Pervious to light frost prevention in low temperature type, suitable for low temperature colorless liquid and light is a good place | |||||||
G | Reflection type cold frost prevention, suitable for low temperature liquid and light color, good place | |||||||
M | Bore diameter, colorless liquid, sensitive instructions, rated pressure 4.0 Mpa or less | |||||||
1 | The high borosilicate glass, T 260 ℃ or less | Testing temperature and glass | ||||||
2 | High borosilicate glass, liquid level and mica sheet | |||||||
3 | Aluminosilicate glass, 260 ℃ or less T 450 ℃ or less | |||||||
4 | Aluminosilicate glass, liquid level and mica sheet | |||||||
3 | Carbon steel Q235 - A | 5 | 321 | Answer the liquid material | ||||
4 | 304 | 6 | 316L | |||||
TB | Top - bottom connection (standard) | The connection form | ||||||
SL | Side - the side left connection type | |||||||
SR | Connection type right side to side | |||||||
EL | Side - the side left with loop connection type | |||||||
ER | Right side side loop connection type | |||||||
-□□□□ | The center distance (mm) | |||||||
left | left | left | left | left | left | left | ||
UB | 25 | A | 4 | 3 | TB | 1100 | Selection for | |
UB series glass level gauge;Pressure rating is Class 150 lb ANSI PN2.5 Mpa;Pervious to light type, suitable for colorless transparent liquid measurement, and the light good place;Aluminosilicate glass, liquid level and mica sheet;Answer the liquid material for carbon steel Q235 - A;Top - bottom connection (standard);Center distance is 1100 mm |