Flame-proof double metal thermometer
One. Product overview
WSSX series explosion-proof electric contact bimetallic thermometer shell adopts aluminium alloy made by aluminum alloy shell inside the meter may produce a spark, arc circuit and watchcase explosive gas mixture is separated, so as to achieve the goal of flame-proof.
Explosion-proof electric contact bimetallic thermometer product performance in line with the BG3836.1-2000 "explosive gas environment with explosion-proof electrical equipment Part 1: general requirements and GB3836.2-2000 "explosive gas environment with explosion-proof electrical equipment Part 2: "d" flameproof electrical equipment "standard.
Explosion-proof electric contact bimetallic thermometer with electric contact device, mechanical electric contact.When the temperature measured medium, fine axis and steering transmission mechanism on the free end turns pointer and the moving contact, on the dial indicates that the change in temperature, when with the fixed contact (upper and lower limit contact) contact or disconnect the instantaneous, relay and contactor in the circuit system action, in order to achieve the purpose of automatic control and alarm.
WSSX series explosion-proof electric contact bimetallic thermometer is the use of round made the bimetallic strip end of the spiral tube are fixed, the other free end connected to the pointer, as the change of temperature and rotation, and drive the pointer indicates the single needle type temperature indicating thermometers.Is oil, coking, chemical industry, medicine and so on in the process of enterprise production site such as carbide explosives each - 80 ~ + 500 ℃ within the scope of liquid, steam and gas medium and the temperature measurement of solid surface.
2. The main technical parameters
Dial nominal diameter: 100
Thermal response time: 40 s or less
Level of flame-proof: DIIBT4
Rated power: 10 va
The highest working voltage: 220 v
The highest working current: 0.7 A
3. Explosion-proof electric contact bimetallic thermometer product selection table:
WSS | Bimetallic thermometer | ||||||
X | Electric contact | ||||||
4 - | Dial diameter Φ 100 | ||||||
Dial form | 0 | axial | |||||
1 | The radial | ||||||
8 | universal | ||||||
Install the fixed form | 0 | No fixed device | |||||
1 | Movable external thread | ||||||
2 | Movable internal thread | ||||||
3 | Fixed screw thread | ||||||
4 | Fixed flange | ||||||
5 | Card sets of thread | ||||||
6 | Card flange | ||||||
flame-proof | B | ExdiiBT4 flame-proof level | |||||
Contact form of protection | M | Upper and lower (not indicate) | |||||
N | Double limit | ||||||
P | Double threshold |
Note: selection of parameters in the choice after the above model to provide the temperature measurement range of the thermometer (recommended maximum range scale range for normal use temperature of 1.5 ~ 2 times), insert depth, sheath maerial diameter, sheath maerial of material, work pressure measured medium, etc.
4. The measuring temperature range
Type no. | ℃ temperature range | Precision grade | Protecting tube material | Gauge, | Install the device |
WSSX-410B | + 40-80 - + 80-40 - 0 to 50 0-100. 0-150. 0-200. 0-300. 0-400. 0-500. | 1.5 | 1Cr18NI9Ti 304 316 316L Hartz C - 276 - H.AIIoyc-276 | 75 100 150 200 300 400 500 750 1000 | No fixture screw |
WSSX-480B | |||||
WSSX-411B | Movable external thread | ||||
WSSX-481B | |||||
WSSX-412B | Movable internal thread | ||||
WSSX-482B | |||||
WSSX-413B | Fixed flange | ||||
WSSX-483B | |||||
WSSX-414B | Fixed screw thread | ||||
WSSX-484B | |||||
WSSX-415B | Card sets of thread | ||||
WSSX-485B | |||||
WSSX-416B | Card flange | ||||
WSSX-486B |