Armoured thermocouple

WR - K armoured thermocouple can bend, high pressure resistance, heat fast response time and strong …

Description:

One. Product overview

WR - K armoured thermocouple can bend, high pressure resistance, heat fast response time and strong and durable wait for an advantage, armoured thermocouple, thermocouple and fabricated as measure temperature sensor, usually armoured thermocouple and display instrument, recorder and electronic regulator, at the same time, the armored thermocouple also can be used as a prefabricated thermocouple temperature sensing element.Armoured thermocouple can be directly measured in the production of a variety of 0 ℃ ~ 1100 ℃ in the scope of liquid, steam and gas medium, as well as the temperature of the solid surface.
2. The main technical indicators
Temperature measurement range and accuracy

category
Code name
Degree,
The casing diameter mm
The commonly used temperature ℃
The highest use temperature ℃
Allowable deviation
Measuring range ℃
Tolerance values
Platinum rhodium 10 - platinum
WRPK
S
Φ 3 or higher
1100
1200
0-1200.
Plus or minus 1.5 ℃ or plus or minus 1.5% t
Copper nickel chrome - nickel
WREK
E
Φ 3 or higher
600
700
0-700.
Plus or minus 2.5 ℃ or plus or minus 0.75% t
Nickel chrome - nickel silicon
WRNK
K
Φ 3 or higher
800
950
0-900.
Plus or minus 2.5 ℃ or plus or minus 0.75% t
Copper and copper and nickel
WRCK
T
Φ 3 or higher
350
400
Less than 200
If there are no relevant provisions
- 40-350.
±0.75%t
Iron, copper and nickel
WRFK
J
Φ 3 or higher
500
600
0-600.
Plus or minus 2.5 ℃ or plus or minus 0.75% t

Note: the "t" for the absolute value of the measured temperature.
T index number should be negotiated with the factory orders.

Armoured thermocouple thermal response time
Step change in temperature, equivalent to the step change is the thermocouple output changes to 50% of the time required to called thermal response time, with the tau 0.5 said.
Armoured thermocouple thermal response time is not greater than the regulation of the table below:

Tau thermal response time of 0.5 S
Pick up shell
Insulation type
The casing diameter (mm)
2.0
0.4
0.5
3.0
0.6
1.2
4.0
0.8
2.5
5.0
1.2
4.0
6.0
2.0
6.0
8.0
4.0
8.0

Model said