Welcome to Shanghai! Our main products: magnetic shutter level gauge, ultrasonic and magnetic level gauge
86-021-56901458
Address:No. 107 Nanshan Road, Shanghai, Jingan District
Tel:86-021-56901458
Fax:86-021-33250243
Email:13817864195@139.com

Intelligent paperless recorder

Paperless recorder with its abundant display, flexible mode of operation, and strong record, operati…

Description:

Products overview:

Paperless recorder with its abundant display, flexible mode of operation, and strong record, operation, control and management functions, has been extremely extensive application in all walks of life.Absorbed all sorts of paperless recorder of the advantages of both at home and abroad, apply the latest display technology, microelectronics technology, data storage and communication technology, is a complete function, convenient operation, precise and reliable, cost-effective products.
Configuration is rich, have a blue screen and two kinds of color display.Can receive multiple types of dc current, voltage and resistance signal, temperature, pressure, liquid level, flow, and force, torque, displacement and other parameters of display, records, the limited monitoring, reporting, data communications, a signal transmitting and accumulated in the flow function.Mainly by the LCD screen, button, the ARM microprocessor as the core of the main board, the main power supply and outside for the transmitter power, intelligent channel plate, such as large capacity FLASH: channel plate can be equipped with different types of intelligence, choose according to the application requirement.
Second, the function and characteristics:
1. According to large amount of information, friendly interface, simple operation; without pen and paper records, maintenance workload is very small, low operating cost;
2. High brightness monochrome or color TFT LCD screen, CCFL backlight, clear images.
3. The ARM microprocessor, can realize 16-way signal collection, record, display and alarm;
4. Big capacity using 64 MB of FLASH chip storage of historical data, never lose data when power supply drop;
5. The whole universal input isolation, various signal input at the same time, don't need to replace the module, through software configuration;
6. According to data of quantities of numerical range wider, five numerical display: - 9999 ~ 19999;
7. Can be configured, display engineering, engineering units, with flow accumulation;
8. A flashing alarm display, at the same time indicating each channel on the floor, floor, ceiling, ceiling alarm;No.12 relay alarm output;
9. Can be configured at 8 analog output, photoelectric isolation, error is less than + / - 0.2% f. S.
10. Shows high accuracy, the basic error of plus or minus 0.2% f. S.
11. Temperature compensation, optional support compensation signal input, constants, and offers a variety of compensation models, such as superheated steam and saturated steam, pressure compensation and other commonly used compensation model;
12. The built-in GB2312 Chinese character, use whole put together input method;
13. Support external micro printer, manual print data, curve, automatic timing print data and meet the needs of users on-site printing;
14. Equipped with standard USB interface.History data archiving convenient;
15. The standard serial communication interface, RS485 with optical coupling isolation and RS232C;
16. Support the standard ModBus RTU communication protocol (optional), in addition to the support of the company data management software, also supports the configuration software MCGS and kingview, popular;
17. The new type of switching power supply, can in the AC power AC 85 v to 265 v voltage range wide normal work;
18. Provide isolation transmitter DC 24 v power distribution;
19. The whole aluminum casing, through EMCIII level, guarantee the normal work of the instrument in the harsh environment.

Third, technical indicators
3.1. Display
5 "LCD or blue color TFT LCD
Digital display screen, bar chart, real time curve display picture, reaching a total of four basic curve picture
Basic error is less than + / - 0.2% f. S, digital display - the range of 9999-19999
Measurement resolution: 1/60000 bit AD converter
Real-time curve record points and eight file intervals of 0.1 seconds to 60 seconds, 30 seconds to 300 points corresponding to the whole screen curve
Recall curve record interval from 0.1 seconds to 50 seconds can be set up for more than 50 seconds when the optional 1 minute, 5 minutes, 10 minutes, 30 minutes, 60 minutes.Can choose cycle or acyclic two types of records

3.2 the input signal
Input signal including direct current and dc voltage, thermal resistance, thermocouple, far eastone pressure gauge five classes, through the selection of key presses.Universal input isolation, do not need to jump line.
: (4 ~ 20 mA dc current, (0 ~ 10) mA, mA (0 ~ 20)
(1 ~ 5) V, dc voltage (0 ~ 5) V, mV
Thermal resistance: Pt100, Cu100 Cu50, BA1, BA2, G53
Thermocouple: K, S, R, B, N, E, J, T
The other input signal or index number when ordering to indicate.

3.3 alarm output and analog output
Relay output: contact capacity of AC 220 v, 3 a, impedance load
12 output can be configured, can according to the passage of the emergency alarm value set
Analog output can be configured 8 PM, photoelectric isolation, error is less than + / - 0.2%, f. S current output load capacity Ω 450 or less
Voltage output impedance adaptor equipment: Ω should be larger than 2 k
3.4 outside power supply source
24 v DC power supply: used to transmitter power, maximum load capacity or less 200 ma
3.5 communication print interface (optional)
Photoelectric isolation
When ordering RS232 and RS485 standard, indicate
Communication rate 9600192 00576 00115 200 by setting options
Form a complete set of testing software, provide configuration software and application software technical support
Optional Modbus RTU communication protocol with PC communications

3.6 power supply conditions
Instrument for AC 220 v power supply: AC 220 ~ 265 v, the power consumption is less than 25 va
24 v DC 24 v power supply instrument: plus or minus 10%, power consumption is less than 25 va
Note: the actual power consumption related to the instrument to the total number of channels

3.7 environment and others
Operating temperature range: 0 ℃ to 50 ℃
Storage temperature range: - 20 ℃ ~ 70 ℃
Working humidity range: less than 85% r.h., without condensation
The weight of the instrument: the most about 2.8 Kg

3.8 appearance size: 144 * 144 * 262

3.9 recording time
Record the length of time and FLASH memory capacity, interval and input points, calculating formula is as follows:

Four, the main items:

Please repair and remove the instrument, please connect the wire and terminal, with plug, please in the following work, be sure to disconnect the power supply after the operation
1, when connect the earth wire
2, when the paperless recorder and plug terminal wiring terminals
Please check carefully before electrical wiring on the meter is correct
The interval of instrument power and electricity again in 5 seconds
In the following situations should take appropriate shielding measures
1, close to the mains power
2, in the occasion of strong electric field or magnetic field
3, in generating static electricity or ac contactor interference and similar occasions
Do not install the instrument in the following situations
1, the occasion of exposure to direct sunlight
2, temperature and humidity to be above the conditions of use
3, corrosive or flammable gas
4, there is a lot of dust, salt and the occasion of metallicity powder
5, water, oil and chemical liquid easy sputtering to the occasion
6, there is a direct vibration or impact


Find out more about the products, technologies and solutions you need. Please leave us a message

Browse:
Return To The Top