Electric contact bimetallic thermometer

WSSX electric contact bimetallic thermometer used in production field of temperature control and ala…

Description:

Product overview

WSSX electric contact bimetallic thermometer used in production field of temperature control and alarm automatically.Direct measurement of various production process - 80 ~ 500 ℃ range, steam and gas medium temperature.

Features:
Live show temperature, intuitive and convenient;
, automatic cut off power and alarm function;
Safe and reliable, long life;
Many kinds of structure forms, can meet different requirements.

Working principle:
Electric contact bimetallic thermometer is the use of lead contact changes when temperature changes, when contact with the upper and lower limits or disconnected at the same time, make the circuit of relay action, to control and alarm automatically.

The main technical parameters
Product standards: JB/T8803-1998 GB3836-83
Dial, nominal diameter: 100
Precision level: (1.0), 1.5
Thermal response time: 40 s or less
Protection grade: IP55
Work normal atmospheric conditions: temperature - 25 ~ + 55 ℃, relative humidity 85% or less
Set point error: set point error should not exceed the basic error of 1.5 times.
Poor switch: switch difference should not exceed the basic error of 1.5 times.
Repetitive switching: switching repeatability limit range is not greater than the absolute value of the basic error limits 1/2.
Electrical parameters

Rated power VA
The highest voltage V
Maximum allowable current
10
220 a.c
0.7A

Selection of coding
Model named method

WSS

Bimetallic thermometer

X
Electric contact structure
Dial nominal diameter4/5 -
Φ/ф 150 100
Dial form0
The axial (straight)
1
The radial (Angle)
8
Universal (adjustable Angle)
Install the fixed form0
No fixed device
1
Movable external thread
2
Movable internal thread
3
Fixed screw thread
4
Fixed flange
5
Card sets of thread
6
Card flange
Protect the formM
Upper and lower
N
Double limit
P
Double threshold

Remark:
Selection instructions: please provide the model, the dial diameter, precision grade, installation fixed form, temperature measuring range, protection tube material, length, or insert depth.
Type selection, for example: universal, dial diameter Φ 100, 0 ~ 400 ℃ temperature range, 1.5, and activities outside thread M27 x 2, 450 mm length
WSSX - 481, 0 ~ 400 ℃, L = 450, M27 x 2,1.5 level
Type and specification


model
Temperature measurement range
Precision grade
Protecting tube material
specifications
Install fixture
WSSX-400/500
- 80 ~ + 40
- 40 ~ + 80
0 ~ 50
0 ~ 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
1.5
1Cr18Ni9Ti
304
316
316L
Hartz C - 276 -
75
100
150
200
300
400
500
750
1000
No fixed device
WSSX-401/501
WSSX-480/580
WSSX-401/501
Movable external thread
WSSX-411/511
WSSX-481/581
WSSX-402/502
Movable internal thread
WSSX-412/512
WSSX-482/583
WSSX-403/503
Fixed screw thread
WSSX-413/513
WSSX-483/583
WSSX-404/504
Fixed flange
WSSX-414/514
WSSX-484/584
WSSX-405/585
Card sets of thread
WSSX-415/515
WSSX-485/585
WSSX-406/506
Card flange
WSSX-416/516
WSSX-486/586

Note: special form order according to the agreement.
Electric contact connection mode


Find out more about the products, technologies and solutions you need. Please leave us a message

Browse:
Return To The Top

分享到: